Experiment Database

Enter a search term to filter database.

Home | Wiki
View the list of cables
Define wiring
Title Poster Test date Material Experiment Type Platform Temperature Impact Velocity Measurements Layout Authors Site name Comments File location Sponsor
Powder cell 2: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 450 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 3: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 4: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 5: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 6: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 7: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 8: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 9: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 10: 70/30/50 mixture2015-09-16 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 11: 70/30/50 mixture2015-09-17 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 14: 70/30/50 mixture2015-09-17 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 13: 70/30/50 mixture2015-09-17 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 19: 70/30/50 mixture2015-09-17 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 20: 70/30/50 mixture2015-09-17 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 21: 70/30/50 mixture2015-09-17 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 22: 70/30/50 mixture2015-09-17 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 23: 70/30/50 mixture2015-09-18 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell 16: 70/30/50 mixture2015-09-18 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Powder cell sand2015-09-18 XPCI 13mm ssgg 25 650 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, PattonID19, ESRF Imperial
Al on Al impact2016-05-04 XPCI 25mm ssgg 25 500 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, Farbaniec, OlbinadoID19, ESRF Imperial
LW Cu on FLF 14 target2016-05-05 XPCI 25mm ssgg 25 720 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF FLF 14 Imperial
LW Cu on FLF 12 target2016-05-05 XPCI 25mm ssgg 25 700 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF FLF 12 Imperial
LW Cu on FLF 11A target2016-05-05 XPCI 25mm ssgg 25 700 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF FLF 11A Imperial
LW Cu on FLF 19 target2016-05-05 XPCI 25mm ssgg 25 700 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF FLF 19 Imperial
2mm Cu on Sipernat cell (Sip1) w/ Cu top-hat2016-05-06 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Sip1 Imperial
2mm Cu on Rod (Rod1) Cell 12016-05-06 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Rod1 Imperial
2mm Cu on Sphere (Sphere1) Cell 12016-05-06 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Sphere1 Imperial
2mm Cu on Sipernat cell (Sip2) w/ Cu top-hat2016-05-06 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Sip2 Imperial
2mm Cu on Sipernat cell (Sip3) w/ PC top-hat2016-05-07 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Sip3 Imperial
2mm Cu on Sipernat cell (Sip4) w/ PC top-hat2016-05-07 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Sip4 Imperial
2mm Cu on Sipernat cell (Sphere2) w/ PC top-hat2016-05-07 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Sphere2 Imperial
2mm Cu on Sipernat cell (Rod2) w/ PC top-hat2016-05-07 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Rod2 Imperial
2mm Cu on Al cylinder (Al2)2016-05-07 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Al2 Imperial
2mm Cu on SHPB Specimen 12016-05-08 XPCI SHPB 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Imperial
Mg AZ31 on Mg AZ31 Spall 12016-05-08 XPCI 25mm ssgg 25 700 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Mg spall 1 Imperial
2mm Cu on SHPB Specimen 22016-05-08 XPCI SHPB 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, FarbaniecID19, ESRF Imperial
2mm Cu on Wave 22016-05-08 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Wave 2 Imperial
Mg AZ31 on Mg AZ31 Spall 22016-05-08 XPCI 25mm ssgg 25 700 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Mg spall 2 Imperial
2mm Cu on Wave 32016-05-08 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Wave 3 Imperial
Taylor Impact: Al 12016-05-08 XPCI 25mm ssgg 25 450 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Taylor 1 Imperial
Taylor Impact: Al 22016-05-08 XPCI 25mm ssgg 25 450 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Taylor 2 Imperial
Mg AZ31 on Mg AZ31 Spall 32016-05-09 XPCI 25mm ssgg 25 700 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Mg spall 3 Imperial
2mm Cu on Sipernat cell (Rod 4) w/ PC top-hat2016-05-09 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Rod 4 Imperial
3mm Cu on Bead 12016-05-09 XPCI 25mm ssgg 25 600 Imaging      PDV      TC     Eakins, Chapman, Rutherford, Derrick, Duarte, FarbaniecID19, ESRF Bead 1 (1mm bead) Imperial
Sipernat powder cell, 30% density, 0.3mm perturbation2017-03-19 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF Imperial
Sipernat powder target No. 62017-03-19 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF Imperial
Sipernat powder target No. 102017-03-19 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF Imperial
Sipernat powder target No. 32017-03-19 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF Imperial
Sipernat powder target No. 72017-03-20 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF potential lack of PDV Imperial
Sipernat powder target No. 112017-03-20 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF Imperial
Sipernat powder target No. 92017-03-20 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF Imperial
Silicon target No. 122017-03-21 XPCI 25mm ssgg Imaging      PDV      TC     ID19, ESRF should be 4? Imperial
PMMA cavity, 4mm_12017-05-11 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Jetting observed. Achieved much higher impact velocity than expected. Imperial
PMMA cavity, 6mm_22017-05-11 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Imperial
PMMA cavity, 6mm_32017-05-11 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Imperial
PMMA cavity, 6mm_42017-05-12 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Time and date corrected on Tek 7254 after shot. Over-wrote pre-shot for 7254 also. Imperial
PMMA cavity, 3mms_12017-05-12 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF One pellicle completely torn, other small tear but still useable. Laser system not working but used IVV anyway, with good timing. Captured some visible emission. Shimadzu images appear to be ghosted, so will test timing on next shot. Imperial
PMMA_slip_12017-05-12 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Image appeared to be ghosted again. Next shot: shift frames by half a bunch to see if the ghosting can be fixed. Imperial
PMMA cavity, 4mm_22017-05-12 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Ghosting issue fixed. Suggests we need to check RF signal and timing systems are aligned properly at the beginning of each day. Automated system to be developed on future runs. Imperial
PMMA cavity, 4mm_32017-05-12 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Optical imaging failed to capture the event because the timing was not adjusted for the lower velocity. Imperial
PMMA cavity, 3mmc_12017-05-12 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Light gates inserted in wrong order, so optical imaging captured only the end of the event. Foam for image registration ESRF_22_25_54 and FLF_22_26_15. Imperial
PMMA cavity, 3mmc_22017-05-12 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Optical imaging started late, but captured most of the event. Missed the sabot coming in before impact. Imperial
PMMA cavity, 6mm_52017-05-13 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Changed att12 Al filter from 1.4mm to 0.7mm, because of 40um shielding added in front of camera. Imperial
PMMA cavity, 6mm_62017-05-13 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF Using optical imaging again. att12 changed to no filter. Imperial
PMMA cavity, 6mm_72017-05-13 XPCI 10mm 2sgg Imaging      PDV      TC     ID19, ESRF With foam fill Imperial
T1 Spall2018-05-08 XPCI 25mm ssgg 25 477 Imaging      PDV      TC     Eakins, Chapman, RutherfordID19, ESRF
Ti_test: Ti lattice2018-09-05 Ti SLM XPCI 25mm ssgg 25 180.61 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=71525318da414303a0197eaa77ff05b4 Fraunhofer EMI
D1: Fraunhoffer EMI First Ti sample shotview2018-09-05 Ti SLM XPCI 25mm ssgg 25 148.09329877823 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
F2: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 144.840072420036 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
B1: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 147.004777655274 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Flatfield and preshot swapped in scope names Fraunhofer EMI
E1: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 149.012790264498 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
L1: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 141.592920353982 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
L5: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 136.487716105551 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
L4: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 349.956255468067 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
F2v2: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 247.116968698517 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
L5v2: Fraunhoffer EMI Ti latticeview2018-09-06 Ti SLM XPCI 25mm ssgg 25 360.144057623049 Imaging      PDV      TC     viewJacklein, Eakins, ChapmanID19, ESRF Fraunhofer EMI
HexSA6-1: Grenoble ceramic/concrete crackingview2018-09-06 XPCI 25mm ssgg 25 227.963525835866 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
ForceSTD6-2: Grenoble ceramic/concrete crackingview2018-09-06 XPCI 25mm ssgg 25 152.866242038217 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Impact velocity was too large, as the heavier dogbone design has not yet been calibrated. Univ. Grenoble
HexSA6-2: Grenoble ceramic/concrete crackingview2018-09-06 XPCI 25mm ssgg 25 144.543483497952 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
UHPCA-3: Grenoble ceramic/concrete crackingview2018-09-07 XPCI 25mm ssgg 25 117.647058823529 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
ForceSTD6-1: Grenoble ceramic/concrete crackingview2018-09-07 XPCI 25mm ssgg 25 192.895032952901 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
HexSA6-3: Grenoble ceramic/concrete crackingview2018-09-07 XPCI 25mm ssgg 25 194 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
UHPCA-1: Grenoble ceramic/concrete crackingview2018-09-07 XPCI 25mm ssgg 25 77.5193798449612 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
UHPCA-7: Grenoble ceramic/concrete crackingview2018-09-07 XPCI 25mm ssgg 25 193.205602962486 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
ForceSTD6-3: Grenoble ceramic/concrete crackingview2018-09-07 XPCI 25mm ssgg 25 95.389507154213 Imaging      PDV      TC     viewForquin, Eakins, ChapmanID19, ESRF Univ. Grenoble
bas-c-1: Basalt powder, coarseview2018-09-08 XPCI 25mm ssgg 25 739.371534195933 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
bas-f-1: Basalt powder, fineview2018-09-08 XPCI 25mm ssgg 25 745.341614906832 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
tef-c-1: Teflon powder, coarseview2018-09-08 XPCI 25mm ssgg 25 733.048259010385 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
bas-m-1: Basalt powder, mediumview2018-09-08 XPCI 25mm ssgg 25 731.261425959781 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
olv-m-1: Olivine powder, mediumview2018-09-08 Olivine-med XPCI 25mm ssgg 25 746.73304293715 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
olv-f-1: Olivine powder, fineview2018-09-08 XPCI 25mm ssgg 25 744.416873449131 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
olv-uf-1: Olivine power, ultra-fineview2018-09-08 Olivine-uf XPCI 25mm ssgg 25 744.42 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=71525318da414303a0197eaa77ff05b4 Oxford
tef-f-1: Telfon powder, fineview2018-09-08 XPCI 25mm ssgg 25 729.92700729927 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
olv-f-2: Olivine powder, fineview2018-09-08 XPCI 25mm ssgg 25 729.483282674772 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
olv-m-2: Olivine powder, mediumview2018-09-08 Olivine-med XPCI 25mm ssgg 25 172.612197928654 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
olv-uf-2: Olivine powder, ultra-fineview2018-09-08 Olivine-uf XPCI 25mm ssgg 25 201.918223119637 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
sip-b-1: Sipernat powder (loaded)view2018-09-08 XPCI 25mm ssgg 25 584.795321637427 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
4mm6: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 200.133422281521 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
bas-c-2: Basalt powder, coarseview2018-09-09 XPCI 25mm ssgg 25 201.782411299815 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
4md2: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 225.861095426313 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Flatfield take AFTER bunch top-up Oxford
bas-f-2: Basalt powder, fineview2018-09-09 XPCI 25mm ssgg 25 199.501246882793 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
sip-b-2: Sipernat powder (loaded)view2018-09-09 XPCI 25mm ssgg 25 158 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
gla-b-2: Glass microsphere powderview2018-09-09 XPCI 25mm ssgg 25 163.912033875154 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
gla-b-1: Glass microsphere powderview2018-09-09 XPCI 25mm ssgg 25 734.843845682792 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF 1st set of FF shown taken w/o 0.7mm Aluminum in place, 2nd with Oxford
6mm9: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 164.971130052241 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
4mm5: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 395.256916996047 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF 1.4 mm Al for FF Oxford
4md4: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 397.088021178028 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
kcl-2: KCl powderview2018-09-09 XPCI 25mm ssgg 25 804.828973843058 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
6mm10: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 405.95399188092 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
4mm4: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 595.238095238095 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
4mmd3: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 594.94298463064 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
6mm8: Emilio cavityview2018-09-09 XPCI 25mm ssgg 25 589.390962671906 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
DJC Spall L1view2018-09-10 Mg AZ31B XPCI 25mm ssgg 25 364.298724954463 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
DJC Spall T4view2018-09-10 Mg AZ31B XPCI 25mm ssgg 25 364.188163884674 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
DJC Spall L2view2018-09-10 Mg AZ31B XPCI 25mm ssgg 25 590.551181102362 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
DJC Spall T5view2018-09-10 Mg AZ31B XPCI 25mm ssgg 25 585.651537335286 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
sip-b-3: Sipernat powder (loaded)view2018-09-10 XPCI 25mm ssgg 25 470.588235294118 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
sip-b-sq-1: Sipernat powderview2018-09-10 XPCI 25mm ssgg 25 596.718050721034 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
T033 / sip-b 16mm: Sipernat powderview2018-09-10 XPCI 25mm ssgg 25 810.263335584065 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
ID19 Logo: PLAview2018-09-10 XPCI 25mm ssgg 25 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
DJC Spall L3view2018-09-10 Mg AZ31B XPCI 25mm ssgg 25 737.553779963122 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
DJC Spall T1view2018-09-11 Mg AZ31B XPCI 25mm ssgg 25 711.321873147599 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Oxford
2mm2: Emilio off-axis small cavity for abel transformationview2018-09-12 XPCI 25mm ssgg 25 293.7576499388 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF 1.4 Al filter. 3 alignment images on low-power beam: CAM1_09_40_06, CAM1_09_41_13, CAM1_09_47_40 Oxford
A cohen steel/Al perturbation2018-09-12 XPCI 25mm ssgg 25 692.440854010387 Imaging      PDV      TC     viewCohen, Eakins, ChapmanID19, ESRF NRCN
DJC tapered spallview2018-09-12 Mg AZ31B XPCI 25mm ssgg 25 588.523786169691 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF 1.4 Al filter. 3 extra pre-target vac alignment images: CAM1_11_21_13, CAM1_11_23_17, CAM1_11_25_51 Oxford
cyl1: Near-field absorption, PMMA2018-09-12 PMMA rod XPCI 25 Imaging      PDV      TC     viewEakinsID19, ESRF 7.99 mm OD. Shimadzu with Hasselblad lenses and vertical mount, with vertical camera orientation to give wider FoV. http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=71525318da414303a0197eaa77ff05b4 Oxford
Detonator characterisation 1/52020-12-08 Velocimetry 25 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Thales UK
Detonator characterisation 2/52020-12-08 Velocimetry 25 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Thales UK
Detonator characterisation 3/52020-12-08 Velocimetry 25 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Thales UK
Detonator characterisation 4/52020-12-08 Velocimetry 25 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Thales UK
Detonator characterisation 5/52020-12-08 Velocimetry 25 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Thales UK
Ta Taylor test 12019-12-01 Ta Taylor test 25mm ssgg 25 80 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Camera was triggered very early relative to impact time, so no dynamic deformation imaging data was captured. The PDV had high frequency noise. http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=e91b8ccf12a147d094586fdd8921074c AWE
Ta Taylor test 22019-12-02 Ta Taylor test 25mm ssgg 25 175 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Good imaging and PDV data. http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=ae2800f4bf3946838d1c87a9944e114c AWE
Ta Taylor test 32019-12-03 Ta Taylor test 25mm ssgg 200 130 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Good imaging and ok PDV http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=11f22b77f9c446739d9b96e6f39b3c33 AWE
Ta Taylor test 42020-10-26 Ta Taylor test 25mm ssgg 299 168 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Good imaging with the SIMX, no PDV due to probe mount melting. http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=ee399c1c23a04973a20e88a5ce5d7f96 AWE
Ta Taylor test 52021-02-04 Ta Taylor test 25mm ssgg 387 181 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Good imaging, very poor PDV signal - there appears to be 2 ramp features. http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=74fd0905ffb94bfeba05bfcd1d24b095 AWE
Ta Taylor test 62021-02-10 Ta Taylor test 25mm ssgg 534 176 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Good PDV http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=7c06f40b593040ea98c5fd0b3856574b AWE
Ta Taylor test 72021-03-22 Ta Taylor test 25mm ssgg 700 110 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Good imaging and PDV data. http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=5413b6ecfe684c4bb30a670fec8ab313 AWE
Detonator characterisation 1/62021-08-25 Velocimetry 85 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Good data. Thales UK
Detonator characterisation 2/62021-08-25 Velocimetry 85 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Good data. Thales UK
Detonator characterisation 3/62021-08-25 Velocimetry 85 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Good data. Thales UK
Detonator characterisation 4/62021-08-25 Velocimetry -50 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Good data. Thales UK
Detonator characterisation 5/62021-08-25 Velocimetry -50 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Good data. Thales UK
Detonator characterisation 6/62021-08-25 Velocimetry -50 Imaging      PDV      TC     viewEakins, ChapmanThales UK, Green Park Good data. Thales UK
AMH_DEN_RT_TT_12021-09-21 SLM 316L SS Taylor test 25mm ssgg 25 195 Imaging      PDV      TC     viewSmithImpact and Shock Mechanics Laboratory Slower than planned. Good Target PDV, Flyer PDV ok. Imaging only partial due to slower velocity. http://shock.eng.ox.ac.uk:8080/share.cgi?ssid=43be42c1486f4a7bbdb56266631dce0f Oxford
Ta Taylor test 82021-11-04 Ta Taylor test 25mm ssgg 300 178 Imaging      PDV      TC     viewSmith, EakinsImpact and Shock Mechanics Laboratory Good imaging data and PDV. AWE
HIP Zr ring expansion 12021-11-11 HIP Zr Radial Expansion 25mm ssgg 25 701 Imaging      PDV      TC     viewChapman, EakinsImpact and Shock Mechanics Laboratory Successful shot. 100% recovery of Zr ring. Muzzle attachment launched off barrel, which is not ideal. Dstl
PELE 42022-01-06 Steel Ballistic Impact 25mm ssgg 25 1030 Imaging      PDV      TC     viewChapmanImpact and Shock Mechanics Laboratory Used 2 x 3 m barrels MBDA
Test firing of weighted sabot to derisk Taylor test2022-04-22 Test firing 25mm ssgg 25 175 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory Good velocity. Oxford
Ta Taylor test 92022-05-06 Ta Taylor Test 25mm ssgg 25 175 Imaging      PDV      TC     viewEakins, ChapmanImpact and Shock Mechanics Laboratory Light gate 3 triggered early, hence camera and PDV were too early and no data was captured. AWE
Filled PC Taylor test2022-07-21 Taylor test 25mm ssgg 25 176.867116 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF
Fill PC Taylor Test 22022-07-21 Taylor test 25mm ssgg 25 178.259115 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF
Mg spall, Longitudinal 12022-07-21 Plate-impact 25mm ssgg 25 283.908292 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Slight tilt, camera data good.
Mg spall transverse 12022-07-21 Plate-impact 25mm ssgg 25 282.320354 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Good data.
Mg spall longitudinal 22022-07-21 Plate-impact 25mm ssgg 25 378.733743 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Slight tilt, but good data
Mg spall transverse 22022-07-21 Plate-impact 25mm ssgg 25 370.060047 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Data captured
AZ31 Spall Transverse2022-07-21 Plate-impact 25mm ssgg 25 253.27344 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Good data
AZ31B Longitudinal Spall ESRF2022-07-21 Plate-impact 25mm ssgg 25 255.431535 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF
Az31B Transvers Spall ESRF2022-07-21 Plate-impact 25mm ssgg 25 269.503402 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Good data - hint of spall
AZ31 Longitudinal Spall ESRF 276 ms-12022-07-21 Plate-impact 25mm ssgg 25 276.237335 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Good data
AZ31 Longitudinal Spall ESRF 288 ms-12022-07-21 Plate-impact 25mm ssgg 25 287.974615 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Good spall imaging
AZ31 Transverse Spall ESRF 288 ms-12022-07-22 Plate-impact 25mm ssgg 25 287.976492 Imaging      PDV      TC     Eakins, ChapmanID19, ESRF Good spall
MP2 Concrete ESRF 237 ms-12022-07-22 Plate-impact 25mm ssgg 25 236.763576 Imaging      PDV      TC     ID19, ESRF
Porous Concrete S1 250 ms-12022-07-22 Plate-impact 25mm ssgg 25 248.931473 Imaging      PDV      TC     ID19, ESRF
Porous Concrete MP3 400 ms-1 ESRF2022-07-22 Plate-impact 25mm ssgg 25 401.293224 Imaging      PDV      TC     ID19, ESRF
Porous concrete S2 400 ms-1 ESRF2022-07-22 Plate-impact 25mm ssgg 25 403.409956 Imaging      PDV      TC     ID19, ESRF
Porous Concrete S3 335 ms-1 ESRF2022-07-22 Plate-impact 25mm ssgg 25 335.587468 Imaging      PDV      TC     ID19, ESRF Nice data
MP5 Porous Cement2022-07-22 Plate-impact 25mm ssgg 25 339.704393 Imaging      PDV      TC     ID19, ESRF good shot
Filled PC Taylor test 255 m/s ESRF2022-07-23 Taylor test 25mm ssgg 25 255.700184 Imaging      PDV      TC     ID19, ESRF
Vel test shot2022-07-23 Calibration 25mm ssgg 25 638.031492 Imaging      PDV      TC     ID19, ESRF
Velocity test2022-07-23 Calibration 25mm ssgg 25 769.007545 Imaging      PDV      TC     ID19, ESRF
GFRPC 250 ms-1 ESRF2022-07-23 Taylor test 25mm ssgg 25 257.532085 Imaging      PDV      TC     ID19, ESRF 90 degree sample 3, orientated fibres in direction of x-ray.
GFRPV 0 deg 250ms-12022-07-23 Taylor test 25mm ssgg 25 258.769352 Imaging      PDV      TC     ID19, ESRF 0 deg sample projectile s6, fibre direction vertical in gun
GFRPC 90 deg Taylor Test ESRF2022-07-24 Taylor test 25mm ssgg 25 178.534134 Imaging      PDV      TC     ID19, ESRF
PMMA cylindrical void closure LLNL ESRF2022-07-24 Plate-impact 25mm ssgg 25 709.504685 Imaging      PDV      TC     ID19, ESRF Good first shot
PMMA cylindrical void close 2022-07-24 Plate-impact 25mm ssgg 25 750.389353 Imaging      PDV      TC     ID19, ESRF PMMA 2 cavity vertical
LDPE Cavity collapse LLNL ESRF2022-07-24 Plate-impact 25mm ssgg 25 751.240255 Imaging      PDV      TC     ID19, ESRF Amazing imaging
UHMW Cylindirical cavity collapse LLNL ESRF2022-07-24 Plate-impact 25mm ssgg 25 749.095432 Imaging      PDV      TC     ID19, ESRF
Vespecl cylindicial cavity collapse ESRF LLNL2022-07-24 Plate-impact 25mm ssgg 25 749.201323 Imaging      PDV      TC     ID19, ESRF
Vespel Cylindrical cavity collapse ESRF LLNL2022-07-24 Plate-impact 25mm ssgg 25 749.688808 Imaging      PDV      TC     ID19, ESRF
Vel test2022-07-24 Calibration 25mm ssgg 25 306.599408 Imaging      PDV      TC     ID19, ESRF
Vanadium cylindrical cavity collaspe2022-07-25 Plate-impact 25mm ssgg 25 234.167204 Imaging      PDV      TC     ID19, ESRF
Nasa Foam 012022-07-26 Plate-impact 25mm ssgg 25 516.388012 Imaging      PDV      TC     ID19, ESRF Foam collapse, elastic wave and compaction
Shot1- PC tin, no LiF, vel approx 10502022-11-17 Calibration 25mm ssgg 25 1057.667318 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory Significant blow-by. LG signal not clear
Flanged Sabot test shot2022-12-21 Calibration 25mm ssgg 25 401 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory Testing new flanged sabot. Flanges hold pressure, with one O-ring at the rear. Sabot design aims to reduce wait and contamination of the barrel. Some gas blow by.
Flanged Sabot test 012023-02-07 Calibration 25mm ssgg 25 400 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory Some gas escaped?
Flanged sabot test2023-02-08 Calibration 25mm ssgg 25 800 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory Flanged test. Leaks out the front into main vac. Gas pillow presursor in LG.
Double O-ring test2023-02-09 Calibration 25mm ssgg 25 778.472204 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory
Sabot sealing test2023-02-10 Calibration 25mm ssgg 25 768.427969 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory Test shot. more blow-by
Sabot sealing test2023-02-28 Calibration 25mm ssgg 25 1083.021961 Imaging      PDV      TC     Threadingham, ChapmanImpact and Shock Mechanics Laboratory Double F double O test.
Sabot sealing test2023-03-03 Calibration 25mm ssgg 25 1050 Imaging      PDV      TC     Threadingham, ChapmanImpact and Shock Mechanics Laboratory sabot failed, but still sealed
Polycrystal Sn, no backing2023-03-17 Sn Plate-impact 25mm ssgg 25 950 Imaging      PDV      TC     Threadingham, Chapman, LiangImpact and Shock Mechanics Laboratory Got data. First test of PDV array. AWE
Polycrystal Sn2023-04-19 Sn Plate-impact 25mm ssgg 25 903.047561 Imaging      PDV      TC     viewThreadingham, ChapmanImpact and Shock Mechanics Laboratory tin, no backing, 4Ch of PDV AWE
HC-5281 P523-012023-05-10 PMMA Brown XPCI 25mm ssgg 25 334 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF No images. Shutter wasn't open when the camera triggered. Brown
HC-5281 P523-112023-05-10 PMMA Brown XPCI 25mm ssgg 25 478.719561 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 P523-102023-05-11 PMMA Brown XPCI 25mm ssgg 25 333.136385 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 P523-022023-05-11 PMMA Brown XPCI 25mm ssgg 25 390.35456 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 P523-162023-05-11 PMMA Brown XPCI 25mm ssgg 25 635.171736 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 P523-232023-05-11 PMMA Brown XPCI 25mm ssgg 25 329.384858 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 S523-152023-05-11 Sucrose Brown XPCI 25mm ssgg 25 325.728895 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 S523-092023-05-12 Sucrose Brown XPCI 25mm ssgg 25 555.5 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good shot. Monitor scope didn't trigger. Brown
HC-5281 S523-262023-05-12 Sucrose Brown XPCI 25mm ssgg 25 692.991632 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 S523-192023-05-12 Sucrose Brown XPCI 25mm ssgg 25 451.394212 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 S523-202023-05-12 Sucrose Brown XPCI 25mm ssgg 25 603.150036 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Possible debris ahead of sabot observed in LG2 trace. Brown
HC-5281 S523-252023-05-12 Sucrose Brown XPCI 25mm ssgg 25 526.60864 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 S523-022023-05-12 Sucrose Brown XPCI 25mm ssgg 25 313.869478 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF shot lost, no imaging data Brown
HC-5281 S523-032023-05-12 Sucrose Brown XPCI 25mm ssgg 25 313.902939 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 S523-172023-05-12 Sucrose Brown XPCI 25mm ssgg 25 633.077713 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 S523-132023-05-13 Sucrose Brown XPCI 25mm ssgg 25 451.686581 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Sucrose, succesful shot Brown
HC-5281 P523-042023-05-13 PMMA Brown XPCI 25mm ssgg 25 656.606953 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
HC-5281 P523-292023-05-13 PMMA Brown XPCI 25mm ssgg 25 329.679899 Imaging      PDV      TC     viewGuduru, Pilvelait, Neogi, Eakins, Chapman, SmithID19, ESRF Good data. Brown
AM Aluminium spall2023-05-13 AM Aluminium XPCI 25mm ssgg 25 176.26322 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, Sket, Eakins, ChapmanID19, ESRF Good PCI data. No PDV. UC3M
AM Aluminium spall2023-05-13 AM Aluminium XPCI 25mm ssgg 25 232.55814 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, Sket, Eakins, ChapmanID19, ESRF XPCI data captured. UC3M
AM Aluminium spall2023-05-14 AM Aluminium XPCI 25mm ssgg 25 218.579235 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF X-ray images, captured PDV signal. UC3M
Spall_ESRF_1_2_3_a2023-05-14 AM Aluminium XPCI 25mm ssgg 25 234 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF no spall UC3M
Spall_ESRF_Alu_1_2_2_b2023-05-14 AM Aluminium XPCI 25mm ssgg 25 363 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF spall spall spall ! UC3M
Spall_ESRF_Alu_2_spare2023-05-13 AM Aluminium XPCI 25mm ssgg 25 247 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF UC3M
Spall_ESRF_Alu_2_1_a2023-05-14 AM Aluminium XPCI 25mm ssgg 25 411.522634 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF spall recovery UC3M
Spall_ESRF_Alu_1_2_1_a2023-05-14 AM Aluminium XPCI 25mm ssgg 25 333 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF spall inception UC3M
Spall_ESRF_Alu_2_2_a2023-05-14 AM Aluminium XPCI 25mm ssgg 25 225.436784 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF The sabot started slipping while charing breach. We were loosing pressure diff. We closed the main vac and charged to 25 bar instead of 47 planned and fired. Shot was not lost, but sample not spalled. UC3M
Spall_ESRF_Alu_2_2_a2023-05-14 AM Aluminium XPCI 25mm ssgg 25 400 Imaging      PDV      TC     viewRodriguez Martinez, Virazels, Ambikadevi Rajasekharan Nair, SketID19, ESRF no PDV, sample recovery for tomo UC3M
ssgg20230515-s012023-05-15 Sn Plate-impact 25mm ssgg 25 1035.53846 Imaging      PDV      TC     ThreadinghamImpact and Shock Mechanics Laboratory split sabot Oxford
HC-5281 P523-272023-05-15 PMMA Brown XPCI 25mm ssgg 25 484 Imaging      PDV      TC     viewRack, LukicID19, ESRF swapped two laser gates, alsmost lost shock wave. Shock at end of movie. 2x Shimadzu 16 um/px Brown+ID19
tin2023-05-18 Sn Plate-impact 25mm ssgg 25 830 Imaging      PDV      TC     ThreadinghamImpact and Shock Mechanics Laboratory Oxford
cu-sn2023-06-01 Sn Plate-impact 25mm ssgg 25 880 Imaging      PDV      TC     Impact and Shock Mechanics Laboratory AWE
RevGeometry30DegreeTrialShotOne2023-06-19 Al 6061 T6 Radial Expansion 25mm ssgg 25 770 Imaging      PDV      TC     Leggett, Chapman, SmithImpact and Shock Mechanics Laboratory Images go dark after 20us. Velocity to be checked as intended to be 710ms. AWE
40DegRevGeometryShot120thJune2023ELPhD2023-06-20 Al 6061 T6 Radial Expansion 25mm ssgg 25 710 Imaging      PDV      TC     Leggett, Chapman, SmithImpact and Shock Mechanics Laboratory 40Degree Reverse Anvil Shot 1 Clear photos compared to 30deg shot, demonstrating symetrical deformation and the ring expanding. 742 LG Actual Velocity vs 710 Est from Vel Curve AWE
32mm Gun test shot2023-07-06 Plate-impact 25mm ssgg 25 150 Imaging      PDV      TC     ChapmanImpact and Shock Mechanics Laboratory Shake down of 32mm rebuild
Bristol Ho Bilayer Alumina-Epoxy sample2023-07-06 Plate-impact 25mm ssgg 25 129 Imaging      PDV      TC     ChapmanImpact and Shock Mechanics Laboratory Sabot velcoity lower than expected. Bilayer PC impact on Alumina/Epoxy/PMMA target. Bristol
Alumina backed with Aluminium Bristol - Ho2023-07-07 Plate-impact 25mm ssgg 25 132 Imaging      PDV      TC     ChapmanImpact and Shock Mechanics Laboratory PC impact onto a alumina/alumina/PMMA target. Bristol - Ho
AWE Ti TT shot 12023-07-12 Plate-impact 25mm ssgg 25 192 Imaging      PDV      TC     Eakins, Chapman, LeggettImpact and Shock Mechanics Laboratory Successful shot AWE
AWE TT Titatnium shot 2 217 ms-12023-07-13 Plate-impact 25mm ssgg 25 217 Imaging      PDV      TC     Chapman, LeggettImpact and Shock Mechanics Laboratory Good shot, the LG traces were not saved AWE
AWE TT Ti shot 3 245ms-12023-07-13 Plate-impact 25mm ssgg 25 245 Imaging      PDV      TC     Chapman, LeggettImpact and Shock Mechanics Laboratory Good shot AWE
AWE TT Ti64 400K shot42023-07-17 Plate-impact 25mm ssgg 25 222 Imaging      PDV      TC     Chapman, Smith, LeggettImpact and Shock Mechanics Laboratory AWE
AWE TT Ti Shot #5 700K2023-07-18 Plate-impact 25mm ssgg 25 220 Imaging      PDV      TC     Chapman, LeggettImpact and Shock Mechanics Laboratory Had to open lid at 700k on first heating due to front rod temperature falling away. Rear rod PDV adjusted at this point also; signal improved on second heating. Fired at 2nd attempt with superior PDV signal achieved. AWE
Rear View Shot 12023-07-25 Plate-impact 25mm ssgg 25 727 Imaging      PDV      TC     Leggett, Threadingham, ChapmanImpact and Shock Mechanics Laboratory Everything triggered. Good LGs and imaging. AWE
Rear View Test #2 40Deg Anvil2023-07-26 Radial Expansion 25mm ssgg 25 731 Imaging      PDV      TC     Eakins, Chapman, LeggettImpact and Shock Mechanics Laboratory Good shot. Images show bias to bottom indicating it was not symetrical as previous side image shot was. But ring can be seen before black mist covers the entire setup this time. AWE
RM Stripping test 1, 800 m/s2023-07-28 Plate-impact 25mm ssgg 25 791 Imaging      PDV      TC     Chapman, Smith, EakinsImpact and Shock Mechanics Laboratory Everything triggered. No clear fragment in the high speed images though. Dstl
RM Sabot stripper test 22023-08-03 Plate-impact 25mm ssgg 25 747 Imaging      PDV      TC     Chapman, ThreadinghamImpact and Shock Mechanics Laboratory Sabot stripper test, the velcoity was fast, but there still appears to be a large amount of debris coming through afterwards. DSTL
RM shot 4 880 ms-12023-08-09 Plate-impact 25mm ssgg 25 880 Imaging      PDV      TC     Chapman, LiangImpact and Shock Mechanics Laboratory 3x6mm RM HIPed fragment. Tapered sabot stripper. No LED for SimX, interaction chamber windows failed. DSTL
Bristol graded density2023-08-09 Plate-impact 25mm ssgg 25 126 Imaging      PDV      TC     ChapmanImpact and Shock Mechanics Laboratory White alumina epoxy specimen number 4 Bristol
Bristol Functionally graded ceramic 2023-08-09 Plate-impact 25mm ssgg 25 136.6 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory Alumina/Aluminium/PMMA functinoally graded blck. PDV on rear of the PMMA (brass layer) Bristol
New sabot test Wong design 12023-08-09 Plate-impact 25mm ssgg 25 226 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory Success, Phantom v7.6 filmed intact sabot leaving barrel
Sabot test2023-09-05 Plate-impact 25mm ssgg 25 447 Imaging      PDV      TC     Chapman, ThreadinghamImpact and Shock Mechanics Laboratory Some small increases to main vacuum during filling, but dropped after. Possibly O-ring shifting. Clean LG signal. Sealed well. AWE
Test shot 22023-09-06 Plate-impact 25mm ssgg 25 848 Imaging      PDV      TC     Smith, Threadingham, WongImpact and Shock Mechanics Laboratory Some leakage into sabot vac when filling, but was evacuated. At >75bar the main vac started to rise. Rise stopped, but fired before the vacuum dropped. Faster than anticipated. LGs good AWE
test shot 052023-09-26 Plate-impact 25mm ssgg 25 1019.144227 Imaging      PDV      TC     Chapman, ThreadinghamImpact and Shock Mechanics Laboratory Test shot of sabot at 160bar. Camera fielded for gas blast and extrusion AWE
Sabot test 62023-10-03 Plate-impact 25mm ssgg 25 1016.967322 Imaging      PDV      TC     Chapman, ThreadinghamImpact and Shock Mechanics Laboratory fired early when leaked into both main vac and sabot vac. aimed for 160 fired at 148. cloud AWE
TT_TestShot2023-10-13 Taylor test 25mm ssgg 25 250 Imaging      PDV      TC     Chapman, Wong, ThreadinghamImpact and Shock Mechanics Laboratory
PC Sn12023-11-01 Plate-impact 25mm ssgg 25 760 Imaging      PDV      TC     Smith, ThreadinghamImpact and Shock Mechanics Laboratory fired successfully AWE
PC Sn shot12023-11-14 Plate-impact 25mm ssgg 25 760 Imaging      PDV      TC     Chapman, ThreadinghamImpact and Shock Mechanics Laboratory Leaking front seal on O-ring. Shot aborted AWE
PC12023-11-15 Plate-impact 25mm ssgg 25 761 Imaging      PDV      TC     Chapman, Threadingham, LiangImpact and Shock Mechanics Laboratory blow by AWE
Sabot test2023-11-20 Plate-impact 25mm ssgg 25 775.848907 Imaging      PDV      TC     Eakins, Smith, Threadingham, LiangImpact and Shock Mechanics Laboratory sabot leaked into sabot vac. shot aborted AWE
PC sabot test2023-11-22 Plate-impact 25mm ssgg 25 775.728434 Imaging      PDV      TC     Eakins, Threadingham, Liang, WongImpact and Shock Mechanics Laboratory Test successful Testing Polycarbonate sabot with 2mm flyer. previous UHMWPE sabot experienced blowby so swapping back to PC AWE
AR1.0 #1view2023-11-28 PMMA cones XPCI 25mm ssgg 25 693 Imaging      PDV      TC     viewFitzgerald, Liang, Morrison, Eakins, ChapmanID19, ESRF Reported breech and target tank pressures are not correct. Need to update LabVIEW. FLF
AR0.25 #1view2023-11-28 PMMA cones XPCI 25mm ssgg 25 693.082254 Imaging      PDV      TC     viewFitzgerald, Liang, Morrison, Eakins, ChapmanID19, ESRF Great! Mila chuffed as chips. FLF
AR2.0 #1view2023-11-28 PMMA cones XPCI 25mm ssgg 25 698.213627 Imaging      PDV      TC     viewFitzgerald, Liang, Morrison, Eakins, ChapmanID19, ESRF Cheesed as cheese. FLF
AR1.0 #2view2023-11-28 PMMA cones XPCI 25mm ssgg 25 797.376181 Imaging      PDV      TC     viewFitzgerald, Liang, Morrison, Eakins, ChapmanID19, ESRF Really happy. Really. FLF
AR0.25 #2view2023-11-29 PMMA cones XPCI 25mm ssgg 25 784.836369 Imaging      PDV      TC     viewEakins, Chapman, Fitzgerald, Liang, MorrisonID19, ESRF Good jets. FLF
AR2.0 #2view2023-11-29 PMMA cones XPCI 25mm ssgg 25 777.468094 Imaging      PDV      TC     viewEakins, Chapman, Fitzgerald, Morrison, LiangID19, ESRF Wonderful. FLF
WE43 spall #2view2023-11-29 WE43 XPCI 25mm ssgg 25 434.782609 Imaging      PDV      TC     viewEakins, Chapman, Liang, Fitzgerald, MorrisonID19, ESRF
CopperDriverMaterialTestTi64Ring29/11/232023-11-29 Radial Expansion 25mm ssgg 25 900 Imaging      PDV      TC     Leggett, Smith, WongImpact and Shock Mechanics Laboratory -SimX RearView with Photron Side View. Anvil Rear PDV only. First driver material test for Ti ring free expansion (copper). - Sabot Vac started rising at about 130bar of fill. Stopped filling and waited to stabilise. Shot at 180bar with sabot vac at 3e-2. AWE
WE43 spall #4view2023-11-29 WE43 XPCI 25mm ssgg 25 698.176836 Imaging      PDV      TC     viewEakins, Chapman, Heslop, Morrison, Liang, FitzgeraldID19, ESRF
WE43 spall #3view2023-11-29 WE43 XPCI 25mm ssgg 25 403.908 Imaging      PDV      TC     viewEakins, Chapman, LiangID19, ESRF
SN25UM 1mm Mold 2mm hole 22023-11-30 Sucrose Brown XPCI 25mm ssgg 25 641.985876 Imaging      PDV      TC     viewEakins, Chapman, Pilvelait, NeogiID19, ESRF Brown
2023-11-30 Radial Expansion 25mm ssgg 25 900 Imaging      PDV      TC     Leggett, Threadingham, Wong, SmithImpact and Shock Mechanics Laboratory AWE
SN25UM 1mm Mold 2mm hole 32023-11-30 Sucrose Brown XPCI 25mm ssgg 25 699 Imaging      PDV      TC     viewEakins, Chapman, Morrison, Liang, FitzgeraldID19, ESRF Brown
P1123012023-11-30 PMMA Brown XPCI 25mm ssgg 25 470.44064 Imaging      PDV      TC     viewEakins, ChapmanID19, ESRF Good shot Brown
AR1.0 #3view2023-11-30 PMMA cones XPCI 25mm ssgg 25 791.305 Imaging      PDV      TC     viewEakins, Chapman, Liang, FitzgeraldID19, ESRF FLF
SN25UM 1mm MOLD 2mm hole 42023-11-30 Sucrose Brown XPCI 25mm ssgg 25 562.719812 Imaging      PDV      TC     viewEakins, Chapman, Liang, FitzgeraldID19, ESRF Brown
AR0.25 #3view2023-12-01 PMMA cones XPCI 25mm ssgg 25 790.097445 Imaging      PDV      TC     viewEakins, Chapman, Fitzgerald, Liang, Pilvelait, NeogiID19, ESRF Grabby gravy. FLF
P1223022023-12-01 PMMA Brown XPCI 25mm ssgg 25 704.638873 Imaging      PDV      TC     viewPilvelait, Neogi, Eakins, Chapman, Morrison, HeslopID19, ESRF Brown
P1223032023-12-01 PMMA Brown XPCI 25mm ssgg 25 583.118713 Imaging      PDV      TC     viewPilvelait, Neogi, Eakins, Morrison, HeslopID19, ESRF Brown
KW_TT_Test12023-12-01 Taylor test 25mm ssgg 25 289.61279 Imaging      PDV      TC     Wong, Leggett, SmithImpact and Shock Mechanics Laboratory
AWE TT Proof of Concept2023-12-01 Taylor test 25mm ssgg 25 204 Imaging      PDV      TC     Wong, Leggett, SmithImpact and Shock Mechanics Laboratory Taylor rod did not fall off, so proof of concept okay. AWE
SN25UM nomold 1mm hole 52023-12-01 Sucrose Brown XPCI 25mm ssgg 25 567.375887 Imaging      PDV      TC     viewEakins, Chapman, Fitzgerald, Pilvelait, Neogi, LiangID19, ESRF Some lobes Brown
SN25UM nomold 1mm hole 62023-12-01 Sucrose Brown XPCI 25mm ssgg 25 620.058906 Imaging      PDV      TC     viewNeogiID19, ESRF Brown
Aermet driver test with Titanium (CM) ring2023-12-04 Radial Expansion 25mm ssgg 25 900 Imaging      PDV      TC     Leggett, SmithImpact and Shock Mechanics Laboratory Aermet trial, all looks v promising, slight sabot leakage behind still, but better than last week. AWE
Aermet Retest 2mm Ring Move Downstream2024-02-07 Radial Expansion 25mm ssgg 25 900 Imaging      PDV      TC     Leggett, SmithImpact and Shock Mechanics Laboratory Aermet Restest with ring moved 2mm further downstream after previous miss. Nailed it this time but still cant see it through the debris. AWE
35DegAnvilOptimisationShotRearView2024-02-08 Plate-impact 25mm ssgg 25 710 Imaging      PDV      TC     Leggett, Threadingham, SmithImpact and Shock Mechanics Laboratory 35 Degree Anvil rear view shot for optimisation set following workbench reccomendation. Fired under same variables as 30deg and 40deg previously. Trialed the foam + PDV combo setup (holes in foam) and it seems to have worked. Small signal recieved and ring captured without penetrating. Stand off distance needs to be decreased to aid PDV though. AWE
AermetRetest1mmDownstream700msNoSleeves2024-02-09 Plate-impact 25mm ssgg 25 716 Imaging      PDV      TC     Leggett, SmithImpact and Shock Mechanics Laboratory Second aermet retest. Primary changes are vel down to 700ms and no outer sleeves (ring only with a full white spray painted driver) Didnt solve my junk spray issue as hoped when compared to Ally/Cu shot with same geometry and speed (where projectiles compressed/o-rings recovered). Side view clealry shows fragmentation though. AWE
35DegAnvilOptimisationSideView2024-02-13 Radial Expansion 25mm ssgg 25 710 Imaging      PDV      TC     Leggett, SmithImpact and Shock Mechanics Laboratory 35Deg anvil optimisation shot #2 for side view imaging and ring pdv. Clean images and pdv signal back, successful. AWE
PC#32024-02-20 Plate-impact 25mm ssgg 25 740 Imaging      PDV      TC     Threadingham, SmithImpact and Shock Mechanics Laboratory Successful shot. AWE
WhiteRing2024-03-05 Radial Expansion 25mm ssgg 25 765 Imaging      PDV      TC     Leggett, SmithImpact and Shock Mechanics Laboratory White ring with black surround and cylinder. Shot to see if a white coloured ring would be visible through the soot. Success. N.B do NOT paint the edge white next time as it shoots off and gets in the way a little bit. If I can get some paint solution that does not peel off on impact its perfect. AWE
32mm vel test2024-03-05 Calibration 25mm ssgg 25 166.7 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory AWE
32mm 3D printed vel test2024-03-06 Plate-impact 25mm ssgg 25 310 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory AWE
Vel Test 32mm Gun 275ms Target2024-03-06 Plate-impact 25mm ssgg 25 277 Imaging      PDV      TC     Chapman, Wong, LeggettImpact and Shock Mechanics Laboratory Targeted 275ms = 28.75bar. Actual 277ms = 29.3bar.
32mm vel test2024-03-06 Calibration 25mm ssgg 25 245 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory AWE
Conventional TT Test shot Ti Grade 22024-03-11 Taylor test 25mm ssgg 25 42.249 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory John Wong Ti Grade 2 specimen 6mm diam 30mm length First test of the SI-VT - gave a weird velocity value AWE
4mm bore diaphragm breech test2024-03-12 Calibration 25mm ssgg 25 634 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory DSTL
4mm bore test shot2024-03-12 Calibration 25mm ssgg 25 1153 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory 3d printed projectile dstl
4mm bore vel test2024-03-12 Calibration 25mm ssgg 25 1045 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory dstl
2024-03-15 Taylor test 25mm ssgg 25 275 Imaging      PDV      TC     Chapman, Smith, WongImpact and Shock Mechanics Laboratory Ti64 Rod on anvil taylor test imaging and light gates only, impact around 254m/s with target fracturing AWE
AWE TT Ti shot92024-03-19 Taylor test 25mm ssgg 25 197 Imaging      PDV      TC     Chapman, Wong, SmithImpact and Shock Mechanics Laboratory Fired very slow, (197 not 250!) and missed imaging. Lost vacuum and one of the plates moved, apparently disturbing the stripper. So the Taylor rod caught the stripper. AWE
AWE Ti TT shot 10 Conventional2024-03-20 Plate-impact 25mm ssgg 25 210 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory Conventional TT, on 32mm gun, with sabot stripping. Velocity went low. Count up count down timer worked well. AWE
Velocity Test 32mm2024-03-26 Calibration 25mm ssgg 25 253.5 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory AWE
32mm vel test2024-03-26 Calibration 25mm ssgg 25 244 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory awe
AWE TT Ti 2024-03-27 Plate-impact 25mm ssgg 25 251 Imaging      PDV      TC     Chapman, SmithImpact and Shock Mechanics Laboratory Sampel 11 orientation 1 AWE
Test shot2024-04-17 Plate-impact 25mm ssgg 25 529.710994 Imaging      PDV      TC     Threadingham, SmithImpact and Shock Mechanics Laboratory Test shot following reassembly of breach. Some blowby? AWE
SC110 #22024-04-26 Plate-impact 25mm ssgg 25 746.059707 Imaging      PDV      TC     Threadingham, SmithImpact and Shock Mechanics Laboratory Tin Shot. large baseline on central channel again AWE
SN100#22024-04-30 Plate-impact 25mm ssgg 25 746.173318 Imaging      PDV      TC     Threadingham, Smith, LiangImpact and Shock Mechanics Laboratory good
Sc 001#22024-05-02 Plate-impact 25mm ssgg 25 745 Imaging      PDV      TC     Threadingham, SmithImpact and Shock Mechanics Laboratory looks good AWE
AWE Ti TT Conventional 10 238 ms-12024-05-03 Taylor test 25mm ssgg 25 238 Imaging      PDV      TC     Chapman, WongImpact and Shock Mechanics Laboratory sample 12 orienttion 1 awe
PC#62024-05-07 Plate-impact 25mm ssgg 25 746.052164 Imaging      PDV      TC     Threadingham, SmithImpact and Shock Mechanics Laboratory looks good AWE
DD Breech Ally/Cu Test 700ms 2024-05-10 Radial Expansion 25mm ssgg 25 742 Imaging      PDV      TC     Leggett, ThreadinghamImpact and Shock Mechanics Laboratory First shot on an ally/copper target using the DD breech. Huge success. AWE
DD Breech Aermet Ti 900ms Test #12024-05-13 Radial Expansion 25mm ssgg 25 972 Imaging      PDV      TC     Leggett, SmithImpact and Shock Mechanics Laboratory Aermet 1mm with Ti Ring 1mm first test on the DD breech. Worked. Only took me 4 years. AWE